1.
J Chromatogr B Analyt Technol Biomed Life Sci ; 824(1-2): 333-40, 2005 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-16112623

RESUMO

A simple, sensitive, selective, and reproducible reversed-phase high-performance liquid chromatographic (HPLC) method with UV detection was developed for the determination of lorazepam (LZP) in human plasma, using oxazepam (OZP) as internal standard. LZP and OZP were extracted from alkalinized (pH 9.5) spiked and clinical plasma samples using a single step liquid-liquid extraction with a mixture of n-hexane-dichloromethane (70:30%; v/v). Chromatographic separation was performed on a reversed-phase Synergi Max RP analytical column (150 mmx4.6 mm i.d.; 4 microm particle size), using an aqueous mobile phase (10 mM KH2PO4 buffer (pH 2.4)-acetonitrile; 65:35%, v/v) delivered at a flow-rate of 2.5 ml/min. Retention times for OZP and LZP were 10.2 and 11.9 min, respectively. Calibration curves were linear from 10 to 300 ng with correlation coefficients (r2) better than 0.99. The limits of detection (LOD) and quantification (LOQ) were 2.5 and 10 ng/ml, respectively, using 0.5 ml samples. The mean relative recoveries at 20 and 300 ng/ml were 84.1+/-5.5% (n=6) and 72.4+/-5.9% (n=7), respectively; for OZP at 200 ng the value was 68.2+/-6.8% (n=14). The intra-assay relative standard deviations (R.S.D.) at 20, 150 and 270 ng/ml of LZP were 7.8%, 9.8% (n=7 in all cases) and 6.6% (n=8), respectively. The inter-assay R.S.D. at the above concentrations were 15.9%, 7.7% and 8.4% (n=7 in all cases), respectively. Intra- and inter-assay accuracy data were within the acceptance interval of +/-20% of the nominal values. There was no interference from other commonly co-administered anticonvulsant, antimicrobial, antipyretic, and antimalarial drugs. The method has been successfully applied to a pharmacokinetic study of LZP in children with severe malaria and convulsions following administration of a single intravenous dose (0.1 mg/kg body weight) of LZP.


Assuntos
Anticonvulsivantes/sangue , Cromatografia Líquida de Alta Pressão/métodos , Lorazepam/sangue , Espectrofotometria Ultravioleta/métodos , Anticonvulsivantes/administração & dosagem , Anticonvulsivantes/farmacocinética , Calibragem , Criança , Humanos , Injeções Intravenosas , Lorazepam/administração & dosagem , Lorazepam/farmacocinética , Reprodutibilidade dos Testes
2.
Artigo em Inglês | MEDLINE | ID: mdl-15135115

RESUMO

A rapid, sensitive and selective gas chromatographic method with flame ionization detection was developed for the determination of paraldehyde in small blood samples taken from children. Whole blood samples (300 microl) collected in a 3 ml Wheaton glass sample vial were spiked with acetone (internal standard: 15 ng) followed by addition of concentrated hydrochloric acid. The mixture was heated in the sealed airtight sample vial in a water bath (96 Celsius; 5 min) to depolymerize paraldehyde to acetaldehyde. A 2 ml aliquot of the headspace was analyzed by gas chromatography with flame ionization detector using a stainless steel column (3 m x 4 mm i.d.) packed with 10% Carbowax 20 M/ 2% KOH on 80/100 Chromosorb WAW. Calibration curves were linear from 1.0-20 microg (r2>0.99). The limit of detection was 1.5 microg/ml, while relative mean recoveries at 2 and 18 microg were 105.6 +/- 8.4 and 101.2 +/- 5.9%, respectively (n = 10 for each level). Intra- and inter-assay relative standard deviations at 2, 10 and 18 microg were <15%. There was no interference from other drugs concurrently used in children with severe malaria, such as anticonvulsants (diazepam, phenytoin, phenobarbitone), antipyretics/analgesics (paracetamol and salicylate), antibiotics (gentamicin, chloramphenicol, benzyl penicillin) and antimalarials (chloroquine, quinine, proguanil, cycloguanil, pyrimethamine and sulfadoxine). The method was successfully applied for pharmacokinetic studies of paraldehyde in children with convulsions associated with severe malaria.


Assuntos
Cromatografia Gasosa/métodos , Paraldeído/sangue , Calibragem , Criança , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade